control#

The optional control toolkit for Paperboat: the clock dynamics (pid, integrator, lag, delay), transfer functions and state space, filters, nonlinear and discrete blocks, state-space design and estimation, and per-step MPC on the optimization toolkit.

Dynamics and loops#

integrator, lag, delay, observer and rhs have no direct feedthrough, so a feedback loop may pass through them. Every other block has feedthrough (Tustin gives a direct term), so a loop needs one of those in it. A vector signal gets one state per element.

Linear blocks#

Polynomial coefficients and matrices are text params in MATLAB style, coefficients in descending powers: a coefficient list is "1 2 1" or "[1, 2, 1]", a matrix "1 0; 0 1" or "[[1, 0], [0, 1]]". A number for Q or R is that times the identity.

The linear blocks share realize (solver: integrated; tustin: discretized at the step), sample_time (z and Tustin: update every sample_time s and hold between; 0 every step), start (zero, or steady: begin at the steady state for the first input, with no start-up transient) and solver. Filters default to realize = tustin with their edges prewarped, so a cutoff is exact at any step; plants (transfer_fn, zpk, second_order) default to solver.

rhs integrates an ODE you type, x’ = f(t, x, u): f is one expression per state separated by ; (x1…xn, u1…um, t), x0 the start, and the run’s solver integrates it. state_space also takes an x0 (zero when empty).

Design blocks (lqr, place, kalman_gain, c2d) have no inputs and give matrices as text ("1 2; 3 4"), so their output wires into state_feedback’s K input or binds like a variable.

Linear analysis#

Pick blocks or a subsystem and press Analyse: the Analysis drawer shows its order and stability, gain and phase margins, dc gain, Bode, pole-zero map and step response, for one input → output pair. Each block gives its linear model (the LTI blocks, PID with n > 0, integrator, lag, state_space); stateless blocks (gain, sum…) are linearized by differences. Loops inside the part are solved; a block that has no linear model (median, relay…) is named. The panel is this toolkit’s web/ part, so the entry points appear only when it is installed.

Predictive control#

mpc, lp_step and nmpc solve a problem every clock step with the optimization toolkit’s Workspace. They have no feedthrough: they output the last u, then read y and ref and solve for the next one. Outputs are u, status, iterations and solve_time; a max_time param turns a solve that misses the step into status = "late" while keeping the last u.